Lockout Time 15 Seconds
Valve-on delay time 15 Seconds

Electrical Ratings
Inputs Voltage: 102 to 132 Vac
Current: 150 mA plus burner motor, igniter, and valve loads
Frequency: 60 Hz
Outputs Motor: 120 Vac, 10 full load amps (FLA*), 60 locked rotor amps (LRA) Note – Reduce motor FLA rating by igniter current
Igniter: 120 Vac, 3 A @ 0.7 PF min
Solenoid Valve: 120 Vac, 1 A @ 0.7 PF min
Thermostat Anticipator Current: 0.1 A (If applicable)
Thermostat Voltage: 24 Vac (If applicable)

The Beckett GeniSysâ„¢ Advanced Burner Control is a 120 Vac primary safety control for residential and light commercial oil burners used in boiler, furnace, and water heater applications. The GeniSys is used with a suitable cad cell fl ame sensor to control the oil burner motor, igniter, and optional solenoid valve. It has 24 Vac thermostat terminals (if applicable) compatible with both mechanical and many power stealing thermostats. It can provide interrupted or intermittent duty ignition, and it has a 15-second lockout time.

Replaces Honeywell R7184B1016, R7184B1024, R7184B1032

(48185B – R7184B HONEYWELL THIS PRIMARY CONTROL WAS USED FROM 2004 TO APPROXIMATELY 2008 THIS CONTROL IS NO LONGER AVAILABLE & WAS REPLACED WITH
THE GENISYS CONTROL).

THIS ALSO REPLACES INTERTHERM 624753

REPLACEMENT FOR FROSTFIGHTER 48185B

 